• Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200
  • Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200
  • Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200
  • Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200

Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200

Deira - Dubai - United Arab Emirates

AED471.22 **Reference Price Only

Brand : SCHNEIDER
Model no : EZC250H3200
WhatsApp Enquiry
**IMPORTANT - How We Work : Your enquiry will be listed in RFQ Marketplace , Suppliers will contact you directly with BEST QUOTE in 24 - 48 hrs

Description

Schneider MCCB – EasyPact EZC,EZC250H3200,200A,36kA,3Pole MCCB EZC250H3200

Range of product : EasyPact

product or component type : Circuit breaker

device short name : Easypact EZC250H

circuit breaker name :Easypact EZC250H

device application : Distribution

poles description : 3P

protected poles description : 3t

network type : 

AC

DC

network frequency : 50/60 Hz

[In] rated current : 

250 A at 40 °C

[Ui] rated insulation voltage :

690 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage : 

6 kV conforming to IEC 60947-2

[Ue] rated operational voltage :

550 V AC 50/60 Hz conforming to IEC 60947-2

250 V DC conforming to IEC 60947-2

breaking capacity code : H

breaking capacity : 

10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

30 kA Icu at 125 V DC 1P conforming to IEC 60947-2

30 kA Icu at 250 V DC 2P conforming to IEC 60947-2

36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2

36 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2

85 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2

85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2

[Ics] rated service breaking capacity

5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2

15 kA at 125 V DC conforming to IEC 60947-2

15 kA at 250 V DC conforming to IEC 60947-2

18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2

18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2

12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2

42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2

42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2

suitability for isolation

Yes conforming to IEC 60947-2

utilisation category : 

Category A

trip unit name : TM-D

trip unit technology : Thermal-magnetic

trip unit rating : 200 A at 50 °C

protection type : Overload protection

Short-circuit protection : pollution degree

3 conforming to IEC 60664-1

3 conforming to IEC 947-1

Complementary

control type : Toggle

mounting mode : Fixed

mounting support : Backplate

upside connection : Front

downside connection : Front

mechanical durability : 10000 cycles

electrical durability : 

Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2

connection pitch

35 mm

local signalling

Positive contact indication

neutral protection setting

Without protection

earth-leakage protection

Without

height : 165 mm

width : 105 mm

depth : 60 mm

Mention 800buildingmaterials when calling supplier to get a BEST DEALS

 

Get Quick Quote

Send Enquiry
Globe location
Safety tips for buying
  1. Use a safe location to meet supplier
  2. Avoid cash transactions
  3. Beware of unrealistic offers
  • Request for Quote
    REQUEST FOR QUOTE
  • WhatsApp