• Schneider Circuit breaker Compact NSX100B, 25 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d LV429552

Schneider Circuit breaker Compact NSX100B, 25 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d LV429552

Deira - Dubai - United Arab Emirates

AED277.57 **Reference Price Only

Brand : SCHNEIDER
Model no : LV429552
WhatsApp Enquiry
**IMPORTANT - How We Work : Your enquiry will be listed in RFQ Marketplace , Suppliers will contact you directly with BEST QUOTE in 24 - 48 hrs

Description

Schneider Circuit breaker Compact NSX100B, 25 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d LV429552

Range : ComPact

product name : ComPact NSX

range of product : ComPact NSX100…250

device short name : NSX100B

product or component type :Circuit breaker

device application : Distribution

Number of poles :3P

protected poles description:

3t

[In] rated current

63 A at 40 °C

[Ue] rated operational voltage

690 V AC 50/60 Hz

network type

AC

network frequency

50/60 Hz

suitability for isolation

Yes conforming to EN/IEC 60947-2

utilisation category

Category A

[Icu] rated ultimate short-circuit breaking capacity

15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

Performance level

B 25 kA 415 V AC

trip unit name

TM-D

trip unit technology

Thermal-magnetic

trip unit protection functions

LI

control type

Toggle

Circuit breaker mounting mode

Fixed

Complementary

[Ui] rated insulation voltage

800 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage

8 kV

[Ics] rated service short-circuit breaking capacity

20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2

25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

7.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2

mechanical durability

50000 cycles

electrical durability

10000 cycles at 690 V In

20000 cycles at 690 V In/2

30000 cycles at 440 V In

50000 cycles at 440 V In/2

mounting support

Backplate

upside connection

Front

downside connection

Front

connection pitch

35 mm

protection type

L : for overload protection (thermal)

I : for short-circuit protection (magnetic)

trip unit rating

63 A at 40 °C

Long-time pick-up adjustment type Ir (thermal protection)

Adjustable

[Ir] long-time protection pick-up adjustment range

0.7…1 x In

Long-time protection delay adjustment type tr

Fixed

[tr] long-time protection delay adjustment range

120…400 s at 1.5 x In

15 s at 6 x Ir

Short-time protection pick-up adjustment type Isd

Fixed

[Isd] Short-time protection pick-up adjustment range

500 A

Short-time protection delay adjustment type tsd

Fixed

earth-leakage protection

Without

Number of slots for electrical auxiliaries

5 slot(s)

Width (W)

105 mm

Height (H)

161 mm

Depth (D)

86 mm

net weight

2.05 kg

Environment

standards

EN/IEC 60947

product certifications

CCC

EAC

Marine

overvoltage category

Class II

electrical shock protection class

Class II

pollution degree

3 conforming to IEC 60664-1

IP degree of protection

IP40 conforming to IEC 60529

IK degree of protection

IK07 conforming to IEC 62262

ambient air temperature for operation

-25…70 °C

ambient air temperature for storage

-50…85 °C

relative humidity

0…95 %

operating altitude

0…2000 m without derating

2000 m…5000 m with derating